General Precautions (cont’d)Personal Safety (cont’d) • Avoid accidental starting. Make sure the power switch is in its “OFF” position, and disconnect
General Precautions (cont’d)ServicingMaintain labels and name plates on the generator and engine. These carry important information. If unreadable or
12 General Precautions (cont’d)Installation (cont’d) • If the generator is installed outdoors, it must be weatherproofed and should be soun
General Precautions (cont’d)Mechanical (cont’d) • Do not operate the generator with safety guards removed. While the generator is running, do not
General Precautions (cont’d)Extension CordIf an extension cord (not included) is used, make sure to use only UL approved cords having the correct gau
15 BatteryThis product does not need a battery.
17AssemblyHandle Installation.Floor Mount InstalationStart by installing the handle on theframe with two 8mm bolts.Then install the handle retainer as
19 Operation NOTE: THE PARTS LISTED ABOVE ARE HELPFUL FOR LOCATING THE CONTROLS MENTIONED BELOW. CAUTION: PRIOR TO FIRST USING THE GENERATOR,
Topic Page Limited Warranty 3 Safety Guidelines 5 General Precautions
20 Operation (cont’d)Starting1. Turn the engine switch to the ON position. The engine switch enables and disables the ignition system.OFF: To st
21 Operation (cont’d)StartingStopping Engine4. Operate the Recoil Starter: Pull the starter grip lightly until you feel resistance, then pull br
22 Operation (cont’d)Powering 120 Volt AC Tools And Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and
23 Operation (cont’d)Powering 12 Volt DC tools and Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and a
24Operation (cont’d)Spark Plug ServiceIn order to service the spark plug, you will need a spark plug wrench (commercially available). Recommended spa
25 Inspection, Cleaning, and Maintenance WARNING! ALWAYS MAKE SURE THE ENGINE POWER SWITCH IS IN ITS “OFF” POSITION. DISCONNECT THE SPARK PLUG WI
26 Installation NOTE: PRIOR TO POWERING TOOLS AND EQUIPMENT MAKE SURE THE GENERATOR’S RATED VOLTAGE, WATTAGE AND AMPERAGE CAPACITY IS ADEQUATE
27 Installation (cont’d)Supporting and Mounting Mount the generator on a concrete slab capable of supporting the weight of the generator. The slab mu
28 ComplianceUNITED STATES ENVIRONMENTAL PROTECTION AGENCY, WASHINGTON, DC 20460 2005 Model Year Certifcate of Conformity • Manufacturer: Jiangsu Jia
Horsepower 13Type 4-cycle OHV air-cooled recoil startDisplacement 389ccOil capacity 1.16 quart (1.1 liter)EPA approved yesCurrent Output 120V/240V AC
3Limited Warran tywarrants to the original purchaser who uses the product in a consumerapplication (personal, residential or household usage) that all
General Parts Listing30 APA Part No. DescriptionThis list is provided for reference purposes only. All repairs and part replacement should be per
General Parts Listing31APA Part No.DescriptionPart. NoBAPA3009-B-01-JD FLANGE BOLT (M6X 14) JF340-B-01 APA3009-B-02-JD OIL LEVEL SWITCH ASSY.
General Parts Listing32 APA Part No. DescriptionPart. NoCAPA3009-C-01-JD DUCT COVER JD5000-A-01APA3009-C-02-JD FLANGE BOLT (M8 X 35)
General Parts Listing33 APA Part No. DescriptionPart. NoDAPG3009-D-Ol-JD CRANKSHAFT COMP. JF340-D-02 APG3009-D-02-JD BALANCER WEIGHT
General Parts Listing34 APA Part No. DescriptionPart. NoEAPG3009-E-01-JD COMPRESSION RING A JF390-E-01 APG3009-E-02-JD COMPRESSION RING
General Parts Listing35 APA Part No. DescriptionPart. NoFAPG3009-F-01-JD PIVOT ADJUSTING NUT JF340-F-01 APG3009-F-02-JD ROCKER ARM PIVO
General Parts Listing36 APA Part No. DescriptionPart. NoG APG3009-G-01-JD RECOIL STARTER ASSY. JF340-G-01 APG3009-G-02-JD SETTING SCREW
General Parts Listing37 APA Part No. DescriptionPart. NoH APG3009-H-01-JD SHROUD JF340-H-01 APG3009-H-02-JD FLANGE BOLT (M6 X 14)
General Parts Listing38 APA Part No. DescriptionPart. NoIAPG3009-I-01-JD TUBE CLIP JD3800-B-01 APG3009-I-02-JD TUBE A
General Parts Listing39 APA Part No. DescriptionPart. NoJAPG3QO9-J-01-JD FLYWHEEL JF340-J-01A APG3QO9-J-02-JD FLYWHEEL JF34
4Limited Warran ty (cont’d)THIS WARRANTY DOES NOT COVER: • Merchandise sold as reconditioned, used as rental equipment, or floor or display models. • M
General Parts Listing40 APA Part No. DescriptionPart. NoKAPG3009-K-01-JD NOISE SUPPERSSOR CAP ASSY. JF340-K-01APG3009-K-02-JD INGITION GOIL
General Parts Listing41 APA Part No. DescriptionPart. NoMAPG3009-M-01-JD CONTROL ASSY. JF340-M-01B APG3009-M-02-JD CONTROL BASE COMP
General Parts Listing42 APA Part No. DescriptionPart. NoN APG3009-N-01-JD FLANGE BOLT (M8 X 16) JD3800-B-01 APG3009-N-02-JD FLANGE BOLT
General Parts Listing43 APA Part No. DescriptionPart. NoOAPG3009-O-01-JD AIR CLEANER COVER COMP JD3800-C-01 APG3009-O-02-JD AIR CLEANER
General Parts Listing44 APA Part No. DescriptionPart. NoPAPG3009-P-01-JD FUEL FILLER CAP COMP JD3800-D-01 APG3009-P-02-JD FUEL FILTER
General Parts Listing45 APA Part No. DescriptionPart. NoQ APG3009-Q-01-JD CONTROL PANEL COMP. JD6500BST-E-01 APG3009-Q-02-JD ENGINE SWIT
General Parts Listing46 APA Part No. DescriptionPart. NoRAPG3009-R-01-JD FUEL TANK MOUNTING RUBBER JD3800-F-01 APG3009-R-02-JD FRAME COMP.
General Parts Listing47 APA Part No. DescriptionPart. NoS APG3009-S-01-JD STATOR COVER JD6500-D-01 APG3009-S-02-JD STATORASSY.
General Parts Listing48APA Part No.DescriptionPart. NoAPG3009-S-18-JD HEX.BOLT (M5 X 20) JD3800-G-18 APG3009-S-19-JD VOLT CHANGE TERMINAL B
5Safety Guidelines - DefinitionsThis manual contains important information that you need to know and understand in order to protect YOUR SAFETY and to
6 Carbon MonoxideWhen this tool is running, ensure that the area is well ventilated. Never run the engine in an enclosed area. Run the engine in an o
7General Precautions (cont’d)Gasoline and Oil (cont’d) • Do not smoke, or allow sparks, flames or other sources of ignition around the engin
8 General Precautions (cont’d)Work Area • Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents. • Do not operate
9 General Precautions (cont’d)Electrical Safety (cont’d) • All connections and conduits from the generator to the load must only be installed by train
Comments to this Manuals